These are the default kind of cuvette & 96 well plate stocked by the lidstrom lab as of 11/2013. This approach enables uniform light dose application to 9 wells (a 3-by-3 matrix in a 96-well plate) simultaneously, which can be leveraged to shorten the duration of PDT experiments (Fig. #ID5-STD) Pierce BCA Protein Assay Kit (ThermoFisher Scientific cat. Fluorescence Microplate Reader Comparison Chart. The rate of molecular motion of Protein G slows down when it is bound to antibodies, resulting in an increase of the FP value (Figure 2). M2. #iD5-STD). D SpectraMax® M2 SpectraMax® M2e Multimode Plate Readers User Guide Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part #0112-0102 Rev. White plates reflect the light, enabling even low levels of Luminescence to be detected. Max, FlexStation, Gemini, and earlier instruments as well as import and analysis of data files from FLIPR and Analyst instruments. )Plate dimensions: X6001, X6004, X6011, X7001, X7007, X7020, X7022, X5101, X6026. x. Flexible liquid transfer Using an 8- or 16-channel pipettor, the FlexStation 3 Reader offers added assay flexibility over dispenser-based systems by transferring reagents from 96 or 384 distinct wells in a source plate to a read plate, simultaneously. The drawing shows a standard microplate of 15 mm height covered with a lid. Use standard plate unless you see your type listed. No accessories are needed and SoftMax® Pro Software. #3603) SpectraMax ABS Plus Microplate Reader (Molecular Devices cat. Or scan up to 384 wells at any time to determine the best assay conditions. Learn more. Cross-talk <0. The perfect microplate reader for everyday biochemical assays, cell-based assays, molecular biology and immunoassays. SpectraMax® iD5 Multi-Mode Microplate Reader - Five-Mode Hybrid Microplate Reader with Automatic NFC Filter Identification and Western Blot Capability, Molecular Devices. To maintain confidence in the standards, Molecular Devices recommends having validation plates recertified at one-to Molecular Devices for recertification at our ISO 17025 accredited lab are disassembled, cleaned, calibrated, andthe iD5 reader’s filter system. 312 gain calibration failed. 5032338. 20 attomol ATP per well. Mix samples in microplate wells by user-programmable Automix feature. The wavelength and scanning ranges are from 340–850 nm in 1 nm increments. An additional reference channel for optimizing the light intensity; Auto switch-off of the light source when not in use to extend lifetime; An automated self-check of major components at instrument start-upThe EMax® Plus Microplate Reader delivers a robust solution in an entry level platform. DynaPro ™ Plate Reader III. SpectraMax ABS and ABS Plus Absorbance ELISA Microplate Readers. Related Products: 96 Well Plate Reader. EMax. FLIPR System with the 540-590 nm BP Emission FLIPR Filter installed (Molecular Devices Corporation) Membrane Potential Assay Kit (Molecular Devices Corporation, R-8034) Clear, flat-bottom, black- or clear-wall 384- or 96-well plates (see consumables list in Appendix A) Clear, polypropylene compound plates (see consumables list in Appendix A) Flexibility to read a variety of plate formats. Kinetic assays were read every 20-28 seconds for one hour,The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Suggested plates are black walled. the absorbance at 340 nm at 37 °C was measured every 30 s using SpectraMax M5 Microplate. Supported Plates Microplates having 6, 12, 24, 48, 96, and 384 wells can be used in the. 2. Detect dim samples with unsurpassed sensitivity; Avoid saturation issues with nine orders of dynamic range. A microplate reader that can detect two or more applications is considered a multi-mode plate reader. External Dimensions without lid (mm). Ultraviolet transparent multiwell plates from GreinerThe Accuris SmartReader UV-Vis (model MR9610) is a welcome addition to any lab that is routinely measuring concentration or absorbance in 96 and/or 384 well plates. Powered by a new, optional high-speed EMCCD camera and the new Peak Pro 2 software module, the new FLIPR® Penta High-Throughput Cellular Screening System allows you to measure and analyze peaks of human-derived induced pluripotent stem cells (hiPSCs), differentiated into cardiomyocytes and neurons, up to 100 times per. 96- and 384-well. This offers the potential for fast and convenient measurements of FAAH activity using a 96-well plate spectrophotometer. The VMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm) with 4 filter choices included at time of purchase. On the FlexStation 3 reader, the entire series of reactions is monitored in real time with simultaneous on-board reagent pipetting and luminescence detection (Figure 1). • Specially formulated optically clear polystyrene and treated to provide protein coating capacity. Specialized filters allow for IR fluorescence detection ranging from 10-40 times more sensitive than conventional monochromator detection reader. #CA961) Methods. The SpectraMax ABS readers can be integrated with Molecular Devices StakMax® Microplate Stacker within . 단일 튜브 디스펜싱에서 전체 96 및 384 well 플레이트세척까지 간소화된 Microplate 세척입니다. Wells of 96-well plates (NEST) were pre-coated with 100 μg/ml of collagen solution for 1 hour. 100 μL of each endotoxin standard was added to triplicate wells of an LAL Reagent Grade Multi-well Plate. 100 uL of LAL reagent was then added to the wells containing the endotoxin standards, and the kinetic read was started. BioTek LogPhase 600 microbiology reader measures microbial growth curves in up to four standard 96-well microplates at a time. Create custom fluorescence assays without having to purchase expensive filter sets. Luminometers and fluorimeters allow for readout of luminescence (luciferase readouts) or fluorescence from an entire well of a micro-well plate such as a 96- or 384-well plate. Washers configured for both 96- and 384-well plates. The reader measures both flat and round 96-well microplates and ensures accuracy by automatic lamp calibration prior to. Published Dec 16, 2020 | Updated Dec 16,. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. Part of a plate can be selected so that only a selected area of the plate. Contact our support team with your questions regarding Molecular Devices products and applications. wells across each plate • Enables viewing and tracking of every well in every plate • Reveals additional information on cellular. Molecular Devices SpectraMax M5 Multi-Mode Microplate Reader. We would like to show you a description here but the site won’t allow us. Devices® SPECTRAmax 190 microplate reader at a wavelength of 600 nm. Some will only support one well density (e. Monthly Plate Verification Check (Absorbance Validation Plate) Note: Monthly Plate Verification Check is maintained by Quality Control. 46Click the Read button in the SoftMax Pro3 reader combines Molecular Devices SpectraMax® M5e Multi-Mode Microplate Reader performance with an integrated 8- or 16-channel pipettor into one compact. Molecular Devices delivers a robust screening platform to address real-time kinetic cell-based assays with the FLIPR Tetra® System. Plate and Setup Rack Options Screens with selection of up to four Methods shown. Explore the best practices for running absorbance-based assays how Molecular Devices absorbance readers can be utilized to optimize said absorbance-based assays. Every step is optimized for data acquired from a Molecular Devices microplate reader or data imported from. They can be read by most microplate readers. The Gemini EM can sample a variety of formats, from 6- to 384-well microplates, in different modes, such as endpoint, spectral scan, kinetic, and well scan. Molecular Devices, LLC Plate Formats: 96 or 384 Well Plates; Manifold Channels: Inquire; Dispensing Liquids: Inquire; Citations: Get Quote. #W50-100) SpectraMax® ABS Plus Microplate Reader (Molecular Devices cat. *For Corning UV plates, mean values at 260 nm ranged from 0. From the Windows Start menu, go to All programs > Molecular Devices > SoftMax Pro x. Products Clone Screening Accessories and Consumables Deep-well Plates Deep-well Plates Deep well blocks available in 24, 96 and 384-well formats Product Options. The SpectraMax® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. President of Molecular Devices. A control well was set up to verify. 5 mm left a residual volume of 100 µL in each well of a 96-well plate or 25 µL for a 384-well plate. 0 nm increments Dynamic range > 7 decades Cross-talk < 0. Well scans from the Gemini EM Reader illustrating serial dilution of CHO cells using the Live Cell assay from Molecular Probes Live/Dead (Calcein AM/Ethidium Homodimer-1) assay kit. Both reactions can be easily measured in Molecular Devices’ new SpectraMax® L microplate luminometer. 5°C at 37°C. 0 . The VMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm), with 4 filter choices included at time of purchase. Supersedes 1. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. Transfer the assay plate directly to a bottom-read fluorescence microplate reader for kinetic read-mode or incubate for 10-30 min at 37oC and then read for endpoint read-mode. Wavelength(s):. The Molecular Devices SpectraMax® M5/M5e Microplate Reader was tested for compatibility with Life. The SpectraMax ABS Plus reader was heated to 37ºC prior to setting up the assay. TNF standard curve. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. Make sure toPlate reader instructions Computer. VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Computer Integration Each Molecular Devices microplate reader is shipped with a license key for the SoftMax® Pro Data Acquisition and Analysis Software that you install on the computer that you use to operate the instrument. It also integrates with the. Plate types Flat and round 96-well plates Data output Export to PC Detection system Single channel silicon photodiode Reading speed 25 seconds Software SoftMax Pro Software Shaking None Temperature control None Linearity 0. 4D-Nucleofector 96-well Shuttle: RATE CONTROLLED. The BioTek Synergy H1 multimode microplate reader is modular and upgradable to include variable-bandwidth monochromator optics for fluorescence excitation and emission wavelength selection, plus luminescence and UV-Vis absorbance. 2. VIS absorbance detection. Figure 3. x. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e. UV Plate 96 Well, Flat Bottom, Cs 50. Enable more assay conditions Define individual reagents to be delivered to each well reducing reagent consumption and allowing for more assay conditions to be explored on a single microplate. ; Page 2 Molecular Devices Corporation warrants this product against defects in material or workmanship as follows:. Contents of wells were pipetted up and down several times to mix. minutes and begin reading microplates with seven mouse clicks. The Molecular Devices ThermoMax is an efficient, temperature-regulated, 96 well microplate reader. When a. Absorbance Detection Cartridges combine scanning and broad spectrum wavelength range to address a variety of nucleic acids, proteins, ELISAs and immunoassays found in the laboratory. The equation that allows one to calculate absorbance from % transmittance is. Mode Plate Reader. The SpectraMax® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution designed to expand the boundaries of research capabilities. Well-to-WellPrecision RFULinearity RelativeFluorescenceUnit(RFU)ScaleRatio(GeminiEM,XPS,SpectraMaxM2-M5e, FlexStation3only). An enzyme-linked polyclonal antibody specific for mouse/rat IL-22 was added to the wells and. 001 ABS (displayed), 0. and California)The upgradeable SpectraMax M5 Multi-Mode Microplate Reader comes with the standard five modes of detection with the upgrade option to add HTRF at a later time. 20 plates/hour (2-minute read time) 96-well 1,920 data points/hour 384-well 7,680 data points/hour 1536-well 30,720 data points/hourMicroplate Reader, For Lab. The top- and bottom-reading Gemini EM Microplate. 340 PC384. SpectraMax® Gemini™ EM Microplate Reader, Molecular Devices. For the kinetic and endpoint LAL assays, the ELx808 TM Reader is highly reliable and easy to use. Microplate Readers. 0. x. Detection modalities include absorbance (UV-Vis Abs) and fluorescence intensity (FI). Top or bottom detection is available with a simple click of a button. Click SoftMax Pro Software User Guide. com. Expand Microplates and select the newly created plate. The onboard luminescence detection mode may be used, or, for higher sensitivity, the reader can be equipped with a NanoBRET detection cartridge that offers a 4-fold improvement in limit of quantitation. What are the dimensions of the plate? Code. to each well. None for any other plate (6, 12, 24, 48 well plates) Flex3: Both Top read and Bottom read. Sample by eye within . $542. the use of a reader calibrated with primary NIST and NMI standards. More Product Information. Molecular Devices: EMax Plus: SpectraMax 190: SpectraMax 340PC384: SpectraMax Plus384: VERSAmax: Vmax: Tecan: Sunrise:. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time. Microplate readers, SpectraMax®, with SpectraDrop. Running both standard spectrophotometer and microplate. Molecular Devices Tunable Microplate Reader VersaMax $ 1,495. Published Dec 16, 2020 | Updated Dec 16, 2020. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time resolved fluorescence assays (TRF). The MultiWash+™ Microplate Washer is an automated, compact, quiet, efficient washer with 20 different wash protocol options. 003 fmol 0. 2b,c. Each plate reader or washer is calibrated, inspected, and lubricated—any potential issues . An entire 96-well plate can be processed in less than six seconds. When samples are added to the wells, the Protein G molecules are resuspended and binding occurs. You should ensure that there is enough volume in compound plate wells to operate the IonWorks® system taking into account the dead volume. Integrated stacker option. May require LS-50B…. luminescence for a 96-well plate and 40 msec integration time for a 384-well plate: 0517 Lit. 4ti-0255 96 well assay plate, pyramid flat bottom, clear, non-sterile UV wavelength 4ti-0214 UltraVision Plate 384, black, non -sterile, with UV baseELISA Workflow Using the EMax plus Microplate Reader and MultiWash+ Microplate Washer. The soil was amended with either 1. SpectraMax Paradigm Microplate Reader General specifications User-upgradeable Multi-Mode Detection Platform Technical specifications Optimized Guaranteed* Fluorescence Intensity (FI) (Fluorescein) 96-well (200 µL) 0. 3% in white 96- and 384. REF (SpectraMax. Gemini XPS Reader scans. Microplate readers compatible with 96-well plates Single- to multi-mode readers combine an absorbance plate reader , a luminescence plate reader , and a fluorescence plate. Using the patented PathCheck® Pathlength Measurement Technology, the SpectraMax M5e Microplate Reader transforms each well in a microplate to a fixed. The EMax® Endpoint ELISA Microplate Reader from Molecular Devices, one of the pioneers in microplate detection, offers a ruggedly simple approach to dedicated endpoint assays. Furthermore, VersaMax system is reliable, which means more uptime and lower long-term cost of ownership. SpectraMax M2 & SpectraMax M2e Multi-mode Plate Readers User Guide — 0112-0102 Rev. Mix well by trituration or plate shaker and incubate for 2 to 5 minutes at room temperature, protected from light. This robust system is capable of reading 96 wells, each with its own sample beam and reference detector. Use preconfigured wash, soak, and aspiration protocols or create your own multi-step protocol using the simple touchscreen interface. #i3x) SpectraMax L Microplate Reader (Molecular Devices cat. guaranteed 25 fmol/200 µL fluorescein (125 pM), black 96-well plate; 1 second integration time 15 fmol/75 µL. SpectraMax Paradigm Microplate Reader is a versatile and customizable device that can perform a wide range of detection modes, such as absorbance, fluorescence, luminescence, time-resolved fluorescence, and AlphaScreen. The FlexStation® 3 Multi-Mode Microplate Reader can be used to run the SpectraMax DuoLuc assay in 96- and 384-well formats with high sensitivity and throughput. d. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. 005 OD Normal and Rapid modes, 96- and 384-well plates Fluorescence Read Timing Excitation Filter: 485/20 nm Emission Filter: 528/20 nm 96-well read: 89 sec. Polypropylene deep well plates, round bottom. EIGHT-CHANNEL OPTICS Plate reads as fast as five seconds MICROPLATES OR CUVETTES Use a 96- or 384-well microplate or a standard cuvette The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. Loading Buffer was also added to a set of cell-free wells for background controls. Gemini EM Reader scans. The SpectraMax ABS/ABS Plus Microplate Readers provide fast absorbance detection without the use of filters with monochromator-based wavelength selection for visible and. $3,450. An example of dual-luciferase assay results. Get Quote . 5 second read per plate. 5 ng per well. Erik Koppes, Richard Haas, Jerry Vockley, Lina Ghaloul-Gonzalez approximately 5,000 cells were seeded in 4 replicates in 96-well plates. x. EMax. Microplate Readers include the M3, M4, M5, and M5e models. The Molecular Devices SpectraMax M3 Multi-Mode Microplate Reader is a dual-monochromator, multi-detection microplate reader with full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well microplates. Users can choose to process all plates within the magazine or select a specific number. The SpectraMax® i3x Multi-Mode microplate reader measures spectral-based Absorbance, Fluorescence, and Luminescence with the added functionality of modular upgrades for. 984. The reader can measure flat and round 96-well microplates and ensure accuracy by automatic lamp calibration before each reading. This reader's dual monochromators for. 0112-0126B 8 Chapter1:Introduction TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate. The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. The 6-well plates were incubated at 37ºC for 9 days before picking. The entire Bulk Kit is sufficient for 100 plates (96- and 384-well), or 70 plates (1536-well). 3) At the bottom of the strip, click on "Show. Tristar 3 Multimode Microplate Reader. 150 µL of deionized water was pipetted into each well of a clean 96-well plate. 000 OD ± 1. * Note: Programming the washer with a final aspirate height of 4. 5A spare fuses, 2 cleaning needles, tubing sets for all bottles, cleaning tool for needles. By measuring optical pathlength, it eliminates the last major distinction between microplate readers and spectrophotometers. Instrument settings can beCorning 96-well black microplates with clear bottom (Corning cat. We would like to show you a description here but the site won’t allow us. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. 1. Anticancer drug assay was also conducted using conventional 96-well plates as controls. The IC50s by cell rounding and LysoTracker. 100 fmol luciferase per well. Instrument pricing. It also integrates with the powerful SoftMax Pro Software for. 96-well PCR plates are plastic, heat-resistant multi-well microplates designed for use inside PCR machines or real-time (qPCR) thermocyclers. The instrument reads any standard cuvette, microcuvette, test tube or 96- and 384-well standard or UV transparent microplate over a full 190 to 1000. Applications include ELISA, protein quantification, enzyme kinetics and cell-based assays. Up to 96 well plates, there is often a good signal that can easily be detected, and 96 wells are measured comparatively quickly. Our microplate. The wavelength and scanning ranges are from 340–850 nm in 1 nm increments. All trademarks used herein are the property of. These include real-time PCR, measuring yields of RNA preparations for microarray experiments, reverse transcription PCR (RT-PCR), differential display PCR,. A = 2 - log 10 (%T). 340 PC384. Endpoint, kinetic, spectrum. Janet got excellent results using them and they are only ~$1. The list is a standard grouping supplied by Molecular Devices and includes some which cannot be used on this instrument; they can be deleted. UV-Star ® 96W Microplate, well working volume 25-370 μL; total well volume 392 μL. Temperature control: 4°C above ambient to 45°C. Answer. Through absorbance readings from both the ultraviolet and visible spectrum range, it can determine the concentration of samples, conduct positive or negative detection of antibodies and. xThe SpectraMax® M3 Microplate Reader is the standard for UV/visible multi-mode reader absorbance, providing ultrafast, full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well microplates. SpectraMax i3x Multi-Mode Microplate Reader. 96-well microplate compatible Well read area range: D4. Product Compare 0. Primary considerations when choosing a microplate reader are throughput and flexibility. UV cuvettes are ideally suited for measurements at 260 nm, 280 nm and in the visible range. 5% at 1. 96- & 384-well automated washer, multiwash™+ automated washer, 96- and 384-well plates, washer maintenance kit. Detection of KASP genotyping reactions. M5. SpectraTest FL1 Fluorescence Validation Plate User Guide Molecular DevicesData are shown as the mean ± s. An industry-renowned instrument for monitoring GPCRs and ion channels. Incubation to 70 o C enables high temperature assays such as enzyme kinetics, protein stability/aggregation. Note: SoftMax Pro Software version 6 and 7 also include a searchable help file within the software. Click on the crosshair and move it so that it is centered over the well image. Multimodal plate reader: Yes: 25 mm: Yes—Max. View Product. We would like to show you a description here but the site won’t allow us. Includes PC and software. QuickSync. A Costar® 24-well tissue culture plate with col1 = blanks and doubling cell. What is the dead volume in 96 and 384 well compound plates? Dead volume is 5 micro liters. A. UV absorbance detection. HeLa. Published Dec 16, 2020 | Updated Nov 07, 2022. On the day of the assay, the plate was equilibrated. Robust shaking and consistent temperature control optimize bacteria and yeast cell growth. All readings were taken in clear, polystyrene 96-shallow-well, flat-bottom plates. Component A (2 vials*)Figure 1. For a 96-well plate it takes a total of 27 seconds to switch between wells and then you have to add the actual injection time based on the injection rate entered by the user. Molecular Devices' microplate readers. Deep well blocks available in 24, 96 and 384-well formats An affordable, tunable microplate reader for 96-well format Affordable The robot-compatible VersaMax reader is cost-effective—users never have to buy filters. The SpectraMax i3x Multi-Mode Microplate Reader has been validated for use with the ValitaTiter and ValitaTiter Plus assays. SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. #3693; n = 4 for each standard). Supported Plates Microplates having 6, 12, 24, 48, 96, and 384 wells can be used in the SpectraMax Multi-Mode Microplate Readers. . maximum-illumination-channels. #E010) Pyroplate 96-well microplate (ACC cat. SpectraMax 340PC384 Microplate Reader A versatile 96- and 384-well format absorbance reader let the monochromator tune to that exact wavelength. Absorbance values were read on the SpectraMax iD5 reader using a preconfigured BCA assay protocol (the SpectraMax iD3 reader is also suitable for these assays, as it has the same absorbance performance as the SpectraMax iD5 reader). Spectramax ® Plus microtiter plate reader (Molecular Devices, Sunnyvale, CA) or similar UV-Vis plate reader; SoftMax ® Pro software (Molecular Devices) (optional) UV compatible quartz plate (for example: # R8024; Molecular Devices) or 96-well Costar ® with UV transparent bottom (for example: #3635 ; Corning Inc. e 3370 Costar 96 Well. Mix well by trituration or plate shaker and incubate for 2 to 5 minutes at room temperature, protected from light. Place the microplate in the drawer. Molecular Devices: FlexStation 3: Multimodal: Limited - monochronometer based: N/A:the iD5 reader’s filter system. Molecular Devices L-Max II Luminescence Microplate Reader. The device was able to achieve 3σ limits of detection of ca. Microplate optimization and read height optimization were performed for best results. Before dispensing reagents to the microplate, the VersaMax Reader was powered on and SoftMax Pro GxP. 500 OD ± 3. Recertification service. Read the microplate • Make sure the purple plate adapter (if required for your plate reader) is in the microplate reader drawer. 5 ng per well. PURPOSE. Software Validation. This is equivalent to having 511 built-in filters,The instruments offer 96- and 384-well microplate-to-microplate fluid transfer (8 or 16 wells at a time), and can read microplates having 6, 12, 24, 48, 96, and 384-well formats. Other technologies such as imaging. SUPPORTED PLATES Microplates having 6, 12, 24, 48, 96, and. 7°C (gradient heating design). Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a. High tolerance for contaminants. 5 OD at 492 nm Computer interface USB 2. x. These lab workhorses are used in drug discovery. None for any other plate (6, 12, 24, 48 well plates) Flex3: Both Top read and. The MultiWash+™ Microplate Washer is an automated, compact, quiet, efficient washer with 20 different wash protocol options. SpectraMax ID5 Plate Reader (Molecular Devices). Service Contracts, Preventative Maintenance and. It features fully-automated kinetic reads of the 96-well plate via the WinKQCL TM Software. Features: Standard back plate for use with hand sanitizer, hand lotion, or foam dispensers. Each well of a 96- well microtiter plate is coated with a fluorescently labeled IgG-binding peptide, Protein G. The. A microplate adapter is required in the reading chamber drawer for 96- and 384-well assay plates. Microplates, also known as microtiter plates, are rectangular multi-well plates used in a variety of assays from ELISA to PCR. Refurbished. 9000-0756. SOP Title: Use and Maintenance of a Molecular Devices M5 Plate Reader Document ID: HSL_EQ_005 Version 2. The SpectraMax® M3 Multi-Mode Microplate Reader provides three modes of detection in one platform. Resipher 96x Starter Kit for use with 96-well plates Includes: (1) Resipher Data Hub, (1) Resipher 96x Reader, (3) sterile sensing lids, all cables Turns a 96-well plate into a precise dynamic oxygen consumption reader, measures 96 wells Utilizes Lucid Lab Cloud software for connection to any…. flat-bottom: 50-60 µl. The DynaPro Plate Reader III provides unparalleled levels of productivity and flexibility for the most demanding nanoparticle sizing and protein aggregation tasks such as biotherapeutic formulation, screening of promiscuous inhibitors, and optimization of protein. A standard curve consisting of MCF7 cells seeded from 20 to 20,000 per well in a 96-well plate was linear across the entire range with r 2 = 0. 200, the Bio-Tek µQuant™, the Bio-Rad UltraMark™, the Molecular Devices SPECTRAmax® 190 and 250 plate readers. Upon completion of a plate read, data are delivered to your computer in an Excel-compatible format. 4 (Molecular Devices cat. 96-well) while others have flexibility to. Compact design Minimum volume and maximum throughput with 96- or 384-well microplate compatibility Powerful data. SpectraMax ID5 Plate Reader (Molecular Devices) Description Internal price (Cornell and Cornell affiliates) External Price; SpectraMax ID5 Plate Reader Use: $20/hr: $32/hr. Corning. 5L) MultiWash+. Single or dual wavelength read, kinetic readings, automix, endpoint, and blank pattern, curve fits included with PC Software. 2. White light and fluorescence images of the 6-well plates were captured with the ClonePix 2 System. M5. SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers. Wide range of applications The VersaMax reader covers a wide range of applications: Step 1: Turn on your microplate reader. 96-, 384-, and 1536-well microplates. variety of. The absorbance was then read on the SpectraMax microplate reader at 426 nm, and the resulting OD values for all wells were averaged together to obtain a value of 0. 96 Well Plate Reader found in: Well Plate Reader Accessory, SmartReader™ 96 Microplate Absorbance Reader, SmartReader UV-Vis Microplate Reader, Stratus. F3/F5 Multi-Mode Microplate ReadersAnalyst® Multimode Reader—one of the following: • Acquest or Analyst AD or HT with at least v. Compare. #R8195. 96-, 384-, and 1536-well microplates. Using the patented PathCheck® Pathlength Measurement Technology, the SpectraMax M4 Microplate Reader transforms each well in a microplate to a fixed. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time resolved fluorescence assays (TRF). Use form “26003-02: Molecular Devices Plate Reader Plate Calibration Form” to record material and equipment information. x. Step 4: Add detection antibody – Enzyme-conjugated detection antibody binds to a second site on the. UV Plate 96 Well, Flat Bottom, Cs 50. sdale innersh Triangle Woingham ershire RG41 T United Kingdom 11 umolde. The SpectraMax L reader is easily integrated with the optional StakMax microplate stacker from Molecular Devices for automated multiplate assays. Top reading gives greater sensitivity for 96 well plates, unless you have cells adhering to the bottom of the well. Before dispensing reagents to the microplate, the VersaMax Reader was powered on and. The clear bottom plates offer the advantage of being able to examine the cells by microscopy during the course of the. Calcium flux was measured with a FlexStation 3 Microplate Reader using the Flex (fast kinetic) read type. Plates were read in the SpectraMax M5 microplate reader at 485ex/515em with bottom read. Artel MVS Bundle DM Std/800TSNB Reader Details. Instrument settings can beIntegrating ValitaTiter and Molecular Devices fluorescence polarization (FP) plate readers produces a seamless IgG titer assay setup and optimization. x. 5 pM Luminescence performance Wavelength range 300–850 nm Wavelength selection Choice of simultaneous detection of all wavelengths or selection in 1. 1 fmol luciferase per well. Temperature variation ± 0. Dimensions: 18.